IBM Updates Required for MAS in an MTL Environment
Symptom
IEA437I Error Message When
Varying MTL Devices
Attempting to vary on more than
one MTL device. The first MTL device will vary online but all subsequent
devices will fail with the above error message.
Resolution
IBM has acknowledged that this is erroneous behavior by MVS, in
APAR number OA03749.
Symptom
IEA437I Error Message When
Varying MTL Devices
This problem will occur if the MAS's channel adapter serial number
changes after MVS has varied on the device at least once. The
MAS's serial number would change if the MAS and/or channel
adapter is replaced. Note that this is not an issue with the MAS,
per se, but applies to any MTL device attached to MVS.
Resolution
IBM has acknowledged that this is erroneous behavior by MVS, in
APAR number OA06698.
Symptom
Tape mount hangs / times out using MTL with
OEM Automated Library
This problem will only affect OAM users.
In the Bus-Tech MAS environment, automated mounts are canceling faster than an
actual operator would be able to cancel the mounts. The problems that may result
when too many automated cancels occur include:
Performance issues, or error message CBR6405D - mount time-outs.
Resolution
IBM has acknowledged that this is erroneous behavior by MVS, in
APAR number OA07945.
Symptom
Tape volume capacity incorrect for OAM
object users
This will only affect OAM users also using MTL.
The tape volume capacity may not reflect the esoteric defined tape capacity as
defined in the SETOAM TAPECAPACITY parameter. The tape capacity will default to
the value of 874218 for enhanced capacity media.
Resolution
IBM has acknowledged that this is erroneous behavior by MVS, in
APAR number OA08963. |