ESCON Device Configuration
Errors
Symptom
Symptom: MAS devices cannot be varied online. The ESCON
adapter's LEDs display the message "Channel Online - nn Connections
Open".
Resolution
"nn Connections Open" tells us that the MAS application
has come up configured for nn devices.
"Channel Online" means that the ESCON adapter is successfully
communicating with the mainframe channel.
The most common cause of this problem is a misconfiguration
of one or more ESCON channel parameters in the MAS devices configuration.
You can display the current parameters with the following command:
q config
Index UA Type CU LPAR Port
-------------------------------
Current Values Are:
01 90 3480 04 01 01 NAME=E990 PATH=/tapelib/ VOL=BT T=0
02 91 3480 04 01 01 NAME=E991 PATH=/tapelib/ VOL=BT T=0
Verify that Unit Address, Control Unit Address, LPAR, and
Port values exactly match the mainframe configuration.
|