Message: "System disk RAIDs are not mirroring properly"
Symptom
The following error messages are displayed every time the MAS
is restarted:
btivts: System disk RAIDs are not mirroring properly
btivts: Tape Library filesystems are likely mounted on the wrong disk drives
btivts: Enter Y if you're sure you want to proceed anyway (not recommended)
btivts: Enter anything else to cancel (recommended)
Resolution
Normally, these messages are displayed when one or more of the
MAS system disk RAIDs is not functioning properly.
However, in
MAS releases 3.06-02 and prior, these messages might also be
displayed erroneously if additional software-controlled RAID(s)
(MD devices) have been added to the MAS by the user. If this
is your situation, please contact
Bus-Tech Support for a patch to resolve this problem.
You can verify at any time whether or not the three MAS system
RAIDs are functioning correctly:
Open a superuser terminal session on the
MAS. howto
Enter the following command to check and optionally repair
the MAS system disk RAIDs:
btiraid
Each of the three MAS system disk RAIDs will be checked to make
sure that they are functioning correctly. If btiraid
encounters no problems it will tell you that everything
is functioning correctly.
If btiraid encounters a
correctable problem, it will prompt you as to whether you want
to correct the problem -- reply 'Y' to correct the problem or
'N' to continue without correcting the problem.
If btiraid encounters a problem that is not easily correctable,
it will display a message to that effect. Please contact
Bus-Tech support for more assistance.
Note 1: How to open a superuser terminal session:
- At the MAS console, press the
<ALT+F2> keys.
- At the Run Command prompt, enter the command
superuser.
- Enter the root user's password when prompted.